제품소개
교정서비스
시험서비스
Home > Business Areas >Calibration Service

Calibration Service

Calibration Laboratory

Introduction

· NANGYEAL is a state-accredited calibration service agency in temperature and humidity field by the international standards
   Accreditation No. : KC04-117 (KS Q ISO/IEC 17025)
· It performs calibration procedure based on the international standards
· As a professional manufacturer of temperature & humidity test chamber and controllers, it provides fast A/S and maintenance service (exclusively for NANGYEAL products)

Benefits from obtaining accreditation as calibration laboratories in accordance with international standards

· Lending international credibility to calibration results of accredited calibration laboratories
· Securing credibility of calibration certificates with expression of uncertainties
· Enhancing credibility of measurement results and calibration capabilities by periodically participating in proficiency tests including interlaboratory comparisons at home and overseas
· Reducing export costs by eliminating duplicate inspection through the mutual recognition among countries and regions

Calibration Field and Item (2 Fields /10 Items)

501. Contact Thermometry
501. Contact Thermometry
Classification No. Calibration Item
50101 Temperature generators; oven, chambers, thermal shock tester, isothermal liquid baths, and dry-block calibrators, etc.
50102 Temperature indicators; controllers/recorders/temperature calibrators, etc.
50104 Resistance thermometers; SPRT, IPRT, thermistors, etc.
50105 Thermal expansion thermometers; bimetal thermometer
50107 Temperature transducers
503. Humidity
503. Humidity
Classification No. Calibration Item
50302 Relative humidity hygrometers; polymer thin film hygrometers, digital temperature & humidity hygrometers, etc.
50303 Psychrometers; PRT type
50304 Temperature humidity recorders; hygro-thermograph, digital hygro-thermograph etc.
50305 Dew-point/relative humidity transducers
50306 Humidity generators; constant temperature and humidity chamber, etc.

· As an expert in temperature & humidity field, NANGYEAL has many professionals with exceptional and distinguished talents in the field.
· As a professional institute of constant temperature and humidity chamber, we, based on our extensive knowledge and know-how, provide customer-oriented service and manuals and tips to operate the equipment properly.
· We also provide agent service for articles that cannot be calibrated at NANGYEAL.

※ Accreditation documents are available for download in the Reference Room.

Report Verification Service

· Verification service for customer to confirm the authenticity of calibration reports issued
· Staff in charge : Yim Gi-Dong, Manager
· Contact No : +82-2-6670-0122
· E-mail : kolas03@nyc02.com

How to use Calibration Service

Service on Reservation
Service on Reservation
Calibration by site visit If you have difficulties in sending out the item to us due to using, you can simply provide us with a list of items to be calibrated. We will dispatch our best personnel to your facility and complete the work on site, on the date you designated.
Carry-in reservation Set up a date for calibration service in advance and send the meter or measuring instruments to be calibrated on that date. In doing so, we can save any waiting time.
Courier Service
Once we receive and complete the calibration work on the meter or any measuring instrument you send us, we will ship the item(s) to your address, if you request (Please note that this service is available only for the items suitable for commercial courier service).
Purchase & Calibration
If you require to purchase one of our products first and then proceed with calibration work with that equipment, we will batch process all the service at once.

Calibration Requesting Procedure


What is Calibration

What is Calibration?

Degree of Inconsistency in Measurement

Measuring instrument may give an inconsistent measurement and lose accuracy for various reasons, including frequency of usage, use environment, expiration of service life, etc. Such inconsistency must be checked and corrected through calibration.
Calibration is a measuring technique that compares between a known standard measurement of high precision and the measurement using your instrument. The accuracy and precision of measuring equipment can be attained and maintained only through calibration. The National Accreditation of Calibration Laboratory Scheme was created prepared to serve that purpose. The ultimate goal of the calibration scheme is to secure the homogeneity and performance of products. In order to maintain the precision and accuracy of measuring instrument, users should obtain the traceability with national calibration standards from KRISS (Korea Research Institute of Standards and Science), the national standard institute, and assure the validation of their measuring instrument used in industrial facilities, or certified testing institutes .

What is Accredited Calibration Institute?

An accredited national calibration institute is a calibration laboratory authorized by the state. An accessor certified and state-registered in accordance with the Framework Act on National Standards, the international standards (KS A ISO/IEC 17025), and the standards set by the KOLAS (Korea Laboratory Accreditation Scheme) examines and assesses the quality system and capabilities in technology of the subject organization, and verifies the subject's ability to calibration in specific field.


Calibration Items
Temperature Items
Name Classification No. Measuring Range
Temperature generators
(Ovens, chambers, dry-block calibrators)
50101 -70 ℃ ~ 400 ℃
Temperature indicators
(Controllers/recorders/temperature calibrators)
50102 -70 ℃ ~ 400 ℃
Resistance thermometers 50104 -70 ℃ ~ 400 ℃
Thermal expansion thermometers
(bimetal thermometer)
50105 -50 ℃ ~ 210 ℃
Temperature transducers 50107 -70 ℃ ~ 400 ℃
Humidity Items
Name Classification No. Measuring Range
Relative humidity hygrometers
(Polymer thin film hygrometers, hair, etc.)
50302 (10~98) % R.H. (-40 ~ 150)℃
Psychrometers (PRT type) 50303 20 % R.H. ~ 95 % R.H.
Temperature humidity recorders
(Hygro-thermograph, etc.)
50304 (10~98) % R.H. (-40 ~ 150)℃
Relative humidity transducers 50305 (10~98) % R.H.
Humidity generators
(Constant temperature & humidity chamber, etc.)
50306 (10~98) % R.H. (-70 ~ 180)℃  -70 ℃ ~ 180 ℃